HOME > Products

 

 

1. APPLICATION

Heat transfer oils, Fuel oil heating, Air, gas, steam

2. MAX.TEMPERATURE

760°C

 

 

 Compact and efficient,Circulation heaters maybe used in forced  or natual circulation systems to heat flowing gasses or liquids.
 Screw plug or flanged immersion heater,vessel,insulation,  terminal box, mounting lugs and inlet and outlet connections are included. Installation is simple with only basic wiring and piping connections required.

 An intergral thermostats included on Type 1, 2, 3, 4, 5, 6 items.  An installation and maintenance manual is supplied with each Circulation heater.
 

(1) FEATURES

   - 150lb, 300lb, 600,900[JIS 5K - 30K] carbon steel flange from 2" to 36" sizes

   -  6.5 - 90 watt/square inch elements for various processes.
   -  Thermowell for 3/8" diameter thermostats bulb and thermocouple mounted near outlet for precise process control and/or welded to element sheath for high limit protection.
   -  Flanges on inlet and outlet on certain sizes
   -  Stainless steel heating chamber
   -  Baffles in chamber to increase material velocity
   -  High temperature insulation (over 500 application temperatures)
   -  Stand-off terminal enclosures to locate the termination from the flange
   -  Surface on higher temperature processes
   -  Thermocouple mounted near outlet for precise process control and/or
   -  Welded to element sheath for high-limit protection
   -  Weatherproof outer jacket
   -  Solid State Controls/Control Panels


(2) HEATING APPLICATION :

 Heat transfer oils

 moulding dies and platens,closed loop heat transfer systems for heat  sensitives materials.

 Fuel oil heating

 pre-heating for delivery to burners,pre-heating to pumping viscosity.   Air,gas,steam, process air,boosting temperatures of gasses,steam  super heating

 Water

  Dishwashing and rinsing, hot water storage tanks, process water,
 jacketed kettles.

 Air, gasses, steam

 Process air, boosting temperatures of gasses, steam superheating


(3). CIRCULATION HEATER OF STOCK TYPE
 

TYPE 1

TYPE 2

TYPE 3

TYPE 4

TYPE 5

TYPE 6

 

(4) CIRCULATION HEATER OF STOCK LIST

1. ANSI#150-3"[JIS10K,80A] FLANGE
 

TYPE

PART NUMBER

WATT

VOLT

SIZE

WATER

AIR,STEAM

A

B

C

D

E

F

3KW

220

850

560

410

90

140

160

CK3A-054

ACK3A-054

3KW

440

CK3A-056

ACK3A-056

5KW

220

1100

820

660

90

140

160

CK3A-058

ACK3A-058

5KW

440

CK3A-060

ACK3A-060

7KW

220

1420

1140

990

90

140

160

CK3A-062

ACK3A-062

7KW

440

CK3A-064

ACK3A-064

2. ANSI#150-5"[JIS10K,125A] FLANGE

TYPE

PART NUMBER

WATT

VOLT

SIZE

WATER

AIR,STEAM

A

B

C

D

E

F

9KW

220

1100

760

635

100

170

220

CK5A-046

ACK5A-046

9KW

440

CK5A-047

ACK5A-047

12KW

220

1270

950

635

100

250

220

CK5A-048

ACK5A-048

12KW

440

CK5A-049

ACK5A-049

20KW

220

1520

1230

635

100

400

220

CK5A-052

ACK5A-052

20KW

440

CK5A-053

ACK5A-053

25KW

220

1800

1570

635

100

560

220

CK5A-054

ACK5A-054

25KW

440

CK5A-055

ACK5A-055

30KW

220

2200

1900

635

100

700

220

CK5A-056

ACK5A-056

30KW

440

CK5A-057

ACK5A-057

3. ANSI#150-8"[JIS10K,200A] FLANGE
 

T Y P E

PART NUMBER

WATT

VOLT

S I Z E

WATER

AIR,STEAM

A

B

C

D

E

F

30KW

220

1350

810

810

330

380

390

CK8A-027

ACK8A-027

30KW

440

CK8A-028

ACK8A-028

40KW

220

1520

990

990

330

380

390

CK8A-029

ACK8A-029

40KW

440

CK8A-030

ACK8A-030

50KW

220

1720

1220

1090

330

380

390

CK8A-031

ACK8A-031

50KW

440

CK8A-032

ACK8A-032

60KW

220

1800

1200

1090

330

380

390

CK8A-001

ACK8A-001

60KW

440

CK8A-002

ACK8A-002


4. ANSI#150-10"[JIS10K,250A] FLANGE

T Y P E

PART NUMBER

WATT

VOLT

S I Z E

WATER

AIR,STEAM

A

B

C

D

E

F

K

L

70KW

220

1880

1530

1670

350

200

330

80

330

CK10A-043

ACK10A-043

70KW

440

CK10A-044

ACK10A-044

85KW

220

2070

1700

1850

350

200

330

80

330

CK10A-045

ACK10A-045

85KW

440

CK10A-046

ACK10A-046

105KW

220

2260

1910

2050

350

200

330

80

330

CK10A-047

ACK10A-047

105KW

440

CK10A-048

ACK10A-048

120KW

220

2450

2100

2250

350

200

330

80

330

CK10A-050

ACK10A-049

120KW

440

CK10A-051

ACK10A-050

135KW

220

2650

2290

2450

350

200

330

80

330

CK10A-052

ACK10A-051

135KW

440

CK10A-053

ACK10A-052

5. ANSI#150-12"[JIS10K,300A] FLANGE
 

T Y P E

PART NUMBER

WATT

VOLT

S I Z E

WATER

AIR,STEAM

A

B

C

D

E

F

K

L

100KW

220

2260

1910

2050

370

200

400

80

360

CK12A-048

ACK12A-048

100KW

440

CK12A-049

ACK12A-049

120KW

220

2260

1910

2050

370

200

400

80

360

CK12A-050

ACK12A-050

120KW

440

CK12A-051

ACK12A-051

140KW

220

2260

1910

2050

370

200

400

80

360

CK12A-052

ACK12A-052

140KW

440

CK12A-053

ACK12A-053

160KW

220

2450

2100

2250

370

200

400

80

360

CK12A-054

ACK12A-054

160KW

440

CK12A-055

ACK12A-055

180KW

220

2650

2290

2450

370

200

400

80

360

CK12A-056

ACK12A-056

180KW

440

CK12A-057

ACK12A-057

6. ANSI#150-14"[JIS10K,350A] FLANGE

T Y P E

PART NUMBER

WATT

VOLT

S I Z E

WATER

AIR,STEAM

A

B

C

D

E

F

K

L

120KW

220

2260

1910

2050

380

220

410

90

380

CK12A-048

ACK12A-048

120KW

440

CK12A-049

ACK12A-049

150KW

220

2260

1910

2050

380

220

410

90

380

CK12A-050

ACK12A-050

150KW

440

CK12A-051

ACK12A-051

175KW

220

2260

2050

2050

380

220

410

90

380

CK12A-052

ACK12A-052

175KW

440

CK12A-053

ACK12A-053

220KW

220

2450

2290

2250

380

220

410

90

380

CK12A-054

ACK12A-054

200KW

440

CK12A-055

ACK12A-055

225KW

220

2650

2290

2450

380

220

410

90

380

CK12A-056

ACK12A-056

225KW

440

CK12A-057

ACK12A-057